Features:
Left drain = 93610; right drain = 17610—flexibility for OEM/manufacturing.
Reliable cycles: service, backwash, brine rinse, refill, fast rinse.
Entry into program setup by holding the “Menu/Confirm” and “Manual/Return” buttons for 5 seconds.
Manual regeneration via “Manual/Return” button at any time.
LED dynamic screen indicates service vs regen states.
Button-lock activates after 1 min of inactivity; unlock by holding Up+Down for 5 sec.